    Brand Name : Mitsubishi
    Model Number : FX3U-3A-ADP
    Supply Ability : 10pc/per week
    Price : $50-$500
    Payment Terms : T/T, western union
    • Product Details
    • Company Profile

    High Quality Mitsubishi PLC FX3U-3A-ADP

    High Quality Mitsubishi PLC FX3U-3A-ADP


    High Quality Mitsubishi PLC FX3U-3A-ADP

    A high-precision analog input / output adapter with a resolution of 12-bit binary.
    [Features]
    -Two-channel input (voltage: DC0 to 10V or current: DC4 to 20mA) and one-channel output (voltage: DC0 to 10V or current: DC4 to 20mA) are possible.
    -Input is for each channel. Voltage or current input can be specified.
    -Data can be transferred without a program (without a dedicated instruction).
    [Application]
    -Convenient for converting analog input signals to digital values ​​and digital values ​​to analog output signals.


    Conformity standard

    Conformity standardUL / cUL KC

    Product Specifications

    Analog inputAnalog input rangeVoltage inputDC0-10V (input resistance 198.7kΩ)
    Current inputDC4-20mA (input resistance 250Ω)
    Number of input channels2 channels
    Absolute maximum inputVoltage input-0.5V, + 15V
    Current input-2mA, + 30mA
    Input characteristicsThe input mode (voltage / current input) can be set for each channel.
    Digital output12bit binary
    resolutionVoltage input2.5mV (10V x 1/4000)
    Current input5μA (16mA x 1/3200)
    Comprehensive accuracyVoltage inputAmbient temperature 25 ° C ± 5 ° C: ± 0.5% (± 50mV) for full scale 10V
    Ambient temperature 0 ° C to 55 ° C: ± 1.0% (± 100mV) for full scale 10V
    Current inputAmbient temperature 25 ° C ± 5 ° C: ± 0.5% (± 80μA)
    for full scale 16mA Ambient temperature 0 ° C to 55 ° C: ± 1.0% (± 160μA) for full scale 16mA
    A / D conversion timeWhen connecting FX3U / FX3UC sequencer80 μs x number of input channels used + 40 μs x number of output channels used (data is updated every calculation cycle)
    When connecting FX3S / FX3G / FX3GC sequencer90 μs x number of input channels used + 50 μs x number of output channels used (data is updated every calculation cycle)
    Insulation method・ Insulation between analog input / output section and sequencer by photocoupler
    ・ Insulation between drive power supply and analog input / output section by DC / DC converter
    ・ Non-insulation between each channel
    Analog outputAnalog output rangeVoltage outputDC0-10V (external load resistance 5k-1MΩ)
    Current outputDC4 to 20mA (external load resistance 500Ω or less)
    Number of output channels1 channel
    Output characteristicsThe output mode (voltage / current output) can be set.
    Digital input12bit binary
    resolutionVoltage output2.5mV (10V x 1/4000)
    Current output4μA (16mA x 1/4000)
    Comprehensive accuracyVoltage outputAmbient temperature 25 ° C ± 5 ° C: ± 0.5% (± 50mV) for full scale 10V
    Ambient temperature 0 ° C to 55 ° C: ± 1.0% (± 100mV) for full scale 10V
    External load resistance (Rs) is less than 5kΩ In that case, the following calculation will be increased.
    (Increases by 100 mV per 1%.)
    47 × 100 / (Rs + 47) -0.9 (%)
    Current outputAmbient temperature 25 ° C ± 5 ° C: ± 0.5% (± 80μA)
    for full scale 16mA Ambient temperature 0 ° C to 55 ° C: ± 1.0% (± 160μA) for full scale 16mA
    D / A conversion timeWhen connecting FX3U / FX3UC sequencer80 μs x number of input channels used + 40 μs x number of output channels used (data is updated every calculation cycle)
    When connecting FX3S / FX3G / FX3GC sequencer90 μs x number of input channels used + 50 μs x number of output channels used (data is updated every calculation cycle)
    Insulation method・ Insulation between analog input / output section and sequencer by photocoupler
    ・ Insulation between drive power supply and analog input / output section by DC / DC converter
    ・ Non-insulation between each channel
    Number of I / O occupied points0 points (not related to the maximum number of I / O points in the sequencer)
    Applicable sequencerFX3S, FX3G (Ver.1.20 or later), FX3U (Ver.2.61 or later), FX3GC, FX3UC (Ver.2.61 or later)
    FX3S-CNV-ADP is required to connect to FX3S.
    FX3G-CNV-ADP is required to connect to FX3G.
    An expansion board is required to connect to FX3U and FX3UC-32MT-LT (-2).
    massAbout 0.1kg

    Product Specifications

    power supplyConversion circuit drive power supplyDC24V + 20% -15%
    Connect a DC24V power supply to the 90mA terminal block and supply it.
    Interface drive power supplyDC5V 20mA
    Internal power is supplied from the DC5V power supply of the basic unit.

    Product Specifications

    Ambient temperature0-55 ℃ ・ ・ ・ ・ ・ During operation -25 ~ 75 ℃ ・ ・ ・ ・ ・ During storage
    Relative humidity5 to 95% RH (no condensation) ・ ・ ・ ・ ・ ・ During operation
    Vibration resistantWhen mounting the DIN railFrequency: 10-57HzOne-sided amplitude: 0.035mm X, Y, Z 10 times in each direction (80 minutes in total)
    Frequency: 57-150HzAcceleration: 4.9m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
    At the time of direct mountingFrequency: 10-57HzOne-sided amplitude: 0.075mm X, Y, Z 10 times in each direction (80 minutes in total)
    Frequency: 57-150HzAcceleration: 9.8m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
    Impact resistance147m / s 2 , action time 11ms, sine and cosine half-wave pulse 3 times in each direction of X, Y, Z
    Noise resistanceBased on a noise simulator with a noise voltage of 1,000 Vp-p, a noise width of 1 μs, a rise of 1 ns, and a period of 30 to 100 Hz.
    Withstand voltageBetween all terminals and ground terminal: AC500V 1 minute
    Insulation resistanceBetween all terminals and ground terminal: 5MΩ or more with DC500V insulation resistance tester
    groundClass D grounding (grounding resistance: 100Ω or less) <Common grounding with strong electrical system is not possible>
    Grounding should be dedicated grounding or shared grounding.
    Atmosphere of useNo corrosive or flammable gas, no terrible conductive dust
    Altitude used
    It cannot be used in an environment where the pressure is 2000 m or less and the atmospheric pressure is higher than the atmospheric pressure. It may break down.